The parts of the job
that are not product.
Half of every flocculant problem we are asked to solve is a method problem: the jar test was run wrong, the dose was converted wrong, or the polymer was chosen by price. These are the methods we use ourselves — published so you can check our work.
How to run
a jar test properly.
Six doses, two mixing speeds, one settling time. The version below is the one that correlates with plant performance; the ten-minute version does not.
Procedure
Five ways a jar test lies to you
Too much shear. A stirrer at 400 rpm during flocculation breaks the floc the polymer just built. Use 40 rpm and a paddle, not a bar.
Polymer added as powder. Powder dropped into a jar never dissolves properly. Always dose from a 0.1–0.3% stock solution.
Wrong order. Coagulant then polymer, with 30–90 seconds between them. Reversing the order gives a result that cannot be reproduced in the plant.
Temperature. A jar test at 22 °C does not predict a plant at 8 °C in winter. Note the temperature and expect a higher dose in the cold.
Judging by eye. “Clearer” is not a measurement. Turbidity in NTU, or settled volume in mL/L, or CST in seconds — pick one and record it.
The conversions
every plant needs.
Most quoting errors are unit errors. These are the four that matter, and they are exact.
| Conversion | Formula | Worked example |
|---|---|---|
| mg/L → g/m³ | 1 mg/L = 1 g/m³ (density 1.0) | 60 mg/L = 60 g/m³ = 60 kg per 1,000 m³ |
| Dose → daily consumption | kg/day = dose (g/m³) × flow (m³/d) ÷ 1,000 | 60 g/m³ × 10,000 m³/d = 600 kg/day |
| Daily → bags / containers | bags = kg/day ÷ bag weight | 600 kg ÷ 25 kg = 24 bags/day |
| Product ↔ active content | actual dose = theoretical × standard % ÷ actual % | 30% basis at 28% product: ×30 ÷ 29 = +3.4% on dose |
| Sludge dose basis | kg/t DS = polymer (kg/h) ÷ (sludge (m³/h) × DS% × 1 t/m³) | 40 kg/h ÷ (100 m³/h × 2%) = 20 kg/t DS |
Which of the three
polymer families?
Charge first, molecular weight second, pH and salinity as tie-breakers.
| Situation | Family | Why | Grade |
|---|---|---|---|
| Mineral tailings, coal, sand wash water | Anionic | Solids are negative; PAC destabilises first, then the chain bridges | A1210 / A1610 |
| Biological sludge, DAF float, paper retention | Cationic | Organic colloids are negative but need charge neutralisation as well as bridging | C10 / C30 / C50 |
| pH below 5, or above 3% salt | Non-ionic | Carboxylate groups protonate at low pH; hydrogen bonding is unaffected by salt | N06 / N10 |
| Drinking water | PAC 29% + DW-grade anionic | Only potable-approved grades; NSF required in the US | PAC-29 / A1210-DW |
| Colour and dye removal | PAC + cationic C80 | High charge density flocculates the dye-colloid complex | PAC-28 + C80 |
| High-solid tailings, oil sands | Anionic, high MW | Bridging length dominates when the bed has to be compressed | A2010 |
PAC against alum,
on total cost.
The invoice price is the smallest part of the comparison. Alkalinity, pH correction, sludge volume and dose all move.
Alum is cheaper per tonne and more expensive per cubic metre. The gap is alkalinity: every mg/L of alum consumes about 0.45 mg/L of alkalinity as CaCO₃, which someone has to replace with lime.
PAC is pre-hydrolysed, so it consumes roughly half the alkalinity of alum for the same coagulation job, works across a wider pH band, and forms a denser floc that settles faster. On low-alkalinity water the advantage is large enough that PAC wins on delivered cost even at twice the price per tonne.
Where alum still wins: high-alkalinity water, low colour, and plants that already have alum handling infrastructure and no lime dosing.
| Cost line | Alum | PAC 28% |
|---|---|---|
| Dose for 30 NTU removal | 40–80 g/m³ | 20–50 g/m³ |
| Alkalinity consumed | ~0.45 mg per mg | ~0.20 mg per mg |
| pH correction needed | Often | Rarely |
| Sludge volume | Higher | 10–25% lower |
| Low-temperature performance | Poor below 10 °C | Maintains |
About these guides.
Can I reproduce these guides in a tender document?
Yes, with attribution. The jar-test method and dose conversions are standard practice, not proprietary — we publish them because a buyer who understands the method writes a better specification.
Do you provide MSDS/SDS in other languages?
English as standard; Spanish, Portuguese, Russian and Vietnamese on request for contract volumes. The SDS format follows GHS, so it can be re-labelled for local regulation by your importer.
Why publish this instead of keeping it for sales calls?
Because the plants that call us have usually already tried something that did not work. If they arrive knowing how to run a jar test, the first conversation is about their water rather than about our product.
Want the method run
on your own water?
Send a 2-litre sample and the operating data. We run the jar test in our lab and return the curves, the recommended grade and a dose range — free for qualified projects.
